{"id":9636,"date":"2026-11-28T03:50:56","date_gmt":"2026-11-28T03:50:56","guid":{"rendered":"https:\/\/holobattery.com\/applications\/medical-device-battery-packs\/"},"modified":"2026-11-28T03:50:56","modified_gmt":"2026-11-28T03:50:56","slug":"medical-device-battery-packs","status":"publish","type":"page","link":"https:\/\/holobattery.com\/applications\/medical-device-battery-packs\/","title":{"rendered":"Medical Device Battery Packs"},"content":{"rendered":"<style id=\"hb-applications-css\">.page-header{display:none!important}main.site-main.page,main.site-main.page .page-content{max-width:none!important;width:100%!important;margin:0!important;padding:0!important}.hb-page{--ink:#0B141E;--body:#475569;--mut:#64748B;--line:#E2E8F0;--tint:#F8FAFC;--green:#23A455;--green-ink:#19763D;--green-wash:#ECFDF5;--dark:#0B141E;--on-dark:#CBD5E1;font-family:'Inter',-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,Arial,sans-serif;color:var(--body);font-size:16px;line-height:1.65;background:#fff}.hb-page *,.hb-page *::before,.hb-page *::after{box-sizing:border-box}.hb-page h1,.hb-page h2,.hb-page h3{font-family:'Archivo',-apple-system,\"Segoe UI\",sans-serif;color:var(--ink);letter-spacing:-.02em;line-height:1.15;margin:0;text-wrap:balance}.hb-page p{margin:0}.hb-page img{max-width:100%}.hb-page a{color:var(--green-ink);text-decoration:none}.hb-page a:not(.hb-btn):hover{text-decoration:underline}.hb-page a:focus-visible,.hb-page summary:focus-visible,.hb-page [tabindex]:focus-visible{outline:3px solid var(--green);outline-offset:3px}.hb-wrap{max-width:1120px;margin:0 auto;padding:0 24px}.hb-page .hb-hero{background:var(--dark);color:var(--on-dark);padding:44px 0 0}.hb-page .hb-hero-grid{display:grid;grid-template-columns:1.1fr 1fr;gap:40px;align-items:center;padding-bottom:64px}.hb-page .hb-hero-grid>*{min-width:0}.hb-page .hb-hero h1{color:#fff;font-size:42px;font-weight:700;max-width:22ch}.hb-page .hb-lead{max-width:60ch;margin-top:20px;font-size:18px;line-height:1.6;color:var(--on-dark)}.hb-page .hb-lead strong{color:#fff;font-weight:600}.hb-page .hb-hero-cta{margin-top:28px;display:flex;flex-wrap:wrap;gap:14px}.hb-page .hb-toc{margin-top:22px;display:flex;flex-wrap:wrap;gap:8px}.hb-page .hb-toc a{font-size:13.5px;border:1px solid rgba(255,255,255,.22);color:var(--on-dark);padding:5px 12px;border-radius:9999px}.hb-page .hb-toc a:hover{border-color:var(--green);color:#fff;text-decoration:none}.hb-page .hb-btn{display:inline-block;min-height:48px;max-width:100%;padding:13px 26px;border-radius:8px;font-family:'Archivo',sans-serif;font-weight:600;font-size:15px;line-height:1.5;text-transform:uppercase;letter-spacing:.05em;text-align:center;transition:transform .25s,box-shadow .25s,background .2s}.hb-page a.hb-btn-primary{background:var(--green);color:#fff}.hb-page a.hb-btn-primary:hover{background:var(--green-ink);color:#fff;transform:translateY(-2px);box-shadow:0 6px 20px rgba(35,164,85,.3);text-decoration:none}.hb-page a.hb-btn-ghost{border:1px solid rgba(255,255,255,.35);color:#fff}.hb-page a.hb-btn-ghost:hover{border-color:var(--green);text-decoration:none}.hb-page .hb-mosaic{display:grid;grid-template-columns:repeat(2,1fr);gap:12px}.hb-page .hb-mosaic.four{grid-template-columns:repeat(4,1fr)}.hb-page .hb-mosaic.three>a:first-child{grid-row:span 2;aspect-ratio:auto}.hb-page .hb-mosaic a{display:block;position:relative;background:var(--tint);border-radius:12px;overflow:hidden;aspect-ratio:1\/1;max-width:100%;transition:transform .2s,box-shadow .2s}.hb-page .hb-mosaic a:hover{transform:translateY(-2px);box-shadow:0 10px 24px rgba(0,0,0,.35);text-decoration:none}.hb-page .hb-mosaic img{width:100%;height:100%;object-fit:contain;display:block;padding:6%}.hb-page .hb-mosaic span{position:absolute;left:8px;bottom:8px;right:8px;width:max-content;max-width:calc(100% - 16px);background:rgba(11,20,30,.8);color:#fff;font:600 12px\/1.3 'Inter',sans-serif;padding:4px 8px;border-radius:6px}.hb-page .hb-section-nav{background:#fff;border-bottom:1px solid var(--line)}.hb-page .hb-section-nav .hb-wrap{display:flex;gap:8px 24px;flex-wrap:wrap;padding-top:14px;padding-bottom:14px}.hb-page .hb-section-nav a{font-size:14px;padding:4px 0;color:var(--body)}.hb-page .hb-section-nav a:hover{color:var(--green);text-decoration:none}.hb-page .hb-section-nav a[aria-current=\"page\"]{color:var(--green-ink);font-weight:700;border-bottom:2px solid var(--green)}.hb-page .hb-section-nav~section{scroll-margin-top:20px}.hb-page .hb-sec{padding:56px 0}.hb-page .hb-sec.tint{background:var(--tint)}.hb-page .hb-sec-h{font-size:32px;font-weight:700;max-width:none}.hb-page .hb-sub{margin-top:20px;max-width:none;color:var(--mut);font-size:17px}.hb-page .hb-prose{max-width:none}.hb-page .hb-prose p{margin-top:16px}.hb-page .hb-note{margin-top:16px;font-size:14px;color:var(--mut);max-width:none}.hb-page .hb-kpis{display:grid;grid-template-columns:repeat(4,1fr);gap:16px}.hb-page .hb-kpis div{border:1px solid var(--line);border-radius:12px;padding:20px;background:#fff}.hb-page .hb-kpis b{display:block;font:700 28px 'Archivo',sans-serif;color:var(--green-ink);letter-spacing:-.01em;font-variant-numeric:tabular-nums}.hb-page .hb-kpis span{display:block;margin-top:6px;font-size:14px;color:var(--mut)}.hb-page .hb-tablewrap{margin-top:28px;max-width:100%;overflow-x:auto;border:1px solid var(--line);border-radius:12px;background:#fff}.hb-page table.hb-spec{width:100%;border-collapse:collapse;font-size:15.5px;min-width:640px}.hb-page .hb-spec th,.hb-page .hb-spec td{padding:14px 16px;border-bottom:1px solid var(--line);text-align:left;vertical-align:top}.hb-page .hb-spec thead th{background:var(--tint);font-family:'Archivo',sans-serif;font-weight:600;color:var(--ink);font-size:14.5px}.hb-page .hb-spec tbody tr:last-child td{border-bottom:0}.hb-page .hb-spec td:first-child{font-weight:600;color:var(--ink)}.hb-page .hb-spec td a{font-weight:600}.hb-page .hb-calc{margin-top:28px;border:1px solid var(--line);border-radius:12px;overflow:hidden;background:#fff}.hb-page .hb-calc .hd{background:var(--dark);color:#fff;padding:14px 22px;font:600 15px 'Archivo',sans-serif;letter-spacing:.02em}.hb-page .hb-calc ol{margin:0;padding:18px 22px 18px 44px}.hb-page .hb-calc li{padding:8px 0;border-bottom:1px dashed var(--line);font-size:15.5px}.hb-page .hb-calc li:last-child{border-bottom:0}.hb-page .hb-calc code{font-family:ui-monospace,SFMono-Regular,Menlo,Consolas,monospace;font-size:14px;background:var(--green-wash);color:var(--green-ink);padding:2px 6px;border-radius:4px;white-space:nowrap}.hb-page .hb-calc .res{background:var(--green-wash);padding:14px 22px;font-size:15.5px;color:var(--ink)}.hb-page .hb-calc .res b{color:var(--green-ink)}.hb-page .hb-cover{margin:32px 0 0;padding:0;border-top:1px solid var(--line)}.hb-page .hb-cover>div{display:grid;grid-template-columns:240px 1fr;gap:32px;padding:22px 0;border-bottom:1px solid var(--line)}.hb-page .hb-cover dt{margin:0;font-family:'Archivo',sans-serif;font-weight:600;font-size:17px;color:var(--ink)}.hb-page .hb-cover dd{margin:0;font-size:16px}.hb-page .hb-two{margin-top:28px;display:grid;grid-template-columns:1fr 1fr;gap:24px}.hb-page .hb-two>div{border:1px solid var(--line);border-radius:12px;padding:24px;background:#fff}.hb-page .hb-two h3{font-size:19px;margin-bottom:10px}.hb-page .hb-two ul{margin:10px 0 0;padding-left:20px}.hb-page .hb-two li{margin:6px 0;font-size:15.5px}.hb-page .hb-fail{margin-top:28px;border-top:1px solid var(--line)}.hb-page .hb-fail>div{display:grid;grid-template-columns:220px minmax(0,1fr) 150px;gap:24px;align-items:center;padding:18px 0;border-bottom:1px solid var(--line)}.hb-page .hb-fail b{font-family:'Archivo',sans-serif;font-weight:600;color:var(--ink);font-size:16.5px}.hb-page .hb-fail .track{height:10px;background:var(--line);border-radius:2px;overflow:hidden}.hb-page .hb-fail .track i{display:block;height:100%;background:var(--green)}.hb-page .hb-fail .pct{font-family:'Archivo',sans-serif;font-weight:700;color:var(--ink);font-variant-numeric:tabular-nums}.hb-page .hb-fail .pct span{display:block;font-family:'Inter',sans-serif;font-weight:400;font-size:13.5px;color:var(--mut)}.hb-page .hb-callout{margin-top:32px;background:var(--green-wash);border-left:4px solid var(--green);border-radius:0 8px 8px 0;padding:22px 26px;max-width:none}.hb-page .hb-callout strong{color:var(--green-ink)}.hb-page .hb-case{margin-top:28px;display:grid;grid-template-columns:1fr 1fr;gap:36px;align-items:center;border:1px solid var(--line);border-radius:12px;background:#fff;padding:32px}.hb-page .hb-case img{display:block;width:100%;height:auto;background:var(--tint)}.hb-page .hb-case .tag{font-size:13.5px;font-weight:700;color:var(--green);text-transform:uppercase;letter-spacing:.04em}.hb-page .hb-case h3{margin-top:8px;font-size:24px}.hb-page .hb-case dl{margin:18px 0 0}.hb-page .hb-case dt{font-size:13.5px;font-weight:600;color:var(--mut);margin-top:14px}.hb-page .hb-case dd{margin:2px 0 0;color:var(--ink)}.hb-page .hb-tiers{margin-top:32px;display:grid;grid-template-columns:repeat(3,1fr);gap:24px}.hb-page .hb-tier{border:1px solid var(--line);border-radius:12px;padding:24px;background:#fff}.hb-page .hb-tier .bar{height:8px;background:var(--line);border-radius:2px;overflow:hidden;margin-bottom:18px}.hb-page .hb-tier .bar i{display:block;height:100%;background:var(--green)}.hb-page .hb-tier:nth-child(1) .bar i{width:12%}.hb-page .hb-tier:nth-child(2) .bar i{width:45%}.hb-page .hb-tier:nth-child(3) .bar i{width:100%}.hb-page .hb-tier b{display:block;font-family:'Archivo',sans-serif;font-size:30px;font-weight:700;color:var(--ink);font-variant-numeric:tabular-nums}.hb-page .hb-tier span{display:block;margin-top:8px;font-size:15px;color:var(--mut)}.hb-page .hb-faq{margin-top:28px;border-top:1px solid var(--line)}.hb-page .hb-faq details{border-bottom:1px solid var(--line)}.hb-page .hb-faq summary{cursor:pointer;list-style:none;display:flex;justify-content:space-between;align-items:center;gap:24px;padding:22px 4px;font-family:'Archivo',sans-serif;font-weight:600;font-size:17.5px;color:var(--ink)}.hb-page .hb-faq summary::-webkit-details-marker{display:none}.hb-page .hb-faq summary::after{content:\"+\";flex:none;font-size:24px;color:var(--green);line-height:1;transition:transform .2s}.hb-page .hb-faq details[open] summary::after{transform:rotate(45deg)}.hb-page .hb-faq .a{padding:0 4px 24px;max-width:none;font-size:16px}.hb-page .hb-reading{margin-top:28px;display:grid;grid-template-columns:repeat(2,1fr);gap:20px}.hb-page .hb-reading a,.hb-page .hb-app{border:1px solid var(--line);border-radius:12px;background:#fff;transition:border-color .2s,box-shadow .2s,transform .2s}.hb-page .hb-reading a{display:block;padding:20px 22px;color:var(--ink)}.hb-page .hb-reading a:hover,.hb-page a.hb-app:hover{border-color:var(--green);box-shadow:0 14px 28px rgba(35,164,85,.12);transform:translateY(-2px);text-decoration:none}.hb-page .hb-reading b{display:block;font-family:'Archivo',sans-serif;font-size:16.5px;font-weight:600}.hb-page .hb-reading span{display:block;margin-top:6px;font-size:14.5px;color:var(--mut)}.hb-page .hb-apps{margin-top:32px;display:grid;grid-template-columns:repeat(3,1fr);gap:22px}.hb-page .hb-app{display:flex;flex-direction:column;overflow:hidden;color:var(--body)}.hb-page .hb-app .img{aspect-ratio:4\/3;max-width:100%;background:var(--tint);display:flex;align-items:center;justify-content:center;overflow:hidden}.hb-page .hb-app .img img{width:100%;height:100%;object-fit:contain}.hb-page .hb-app .body{padding:20px 22px 22px;display:flex;flex-direction:column;gap:8px;flex:1}.hb-page .hb-app b{font-family:'Archivo',sans-serif;font-size:19px;font-weight:700;color:var(--ink)}.hb-page .hb-app .v{align-self:flex-start;background:var(--green-wash);color:var(--green-ink);padding:2px 10px;border-radius:9999px;font-size:12.5px;font-weight:600;letter-spacing:.03em;text-transform:uppercase}.hb-page .hb-app p{font-size:15px}.hb-page .hb-app .more{margin-top:auto;padding-top:8px;font-weight:600;color:var(--green-ink);font-size:15px}.hb-page .hb-app.guide{background:var(--tint);justify-content:center}.hb-page .hb-app.guide .body{justify-content:center}.hb-page .hb-related{margin-top:28px;display:flex;flex-wrap:wrap;gap:10px 28px;font-size:15.5px}.hb-page .hb-related a{font-weight:600}.hb-page .hb-quote{background:var(--dark);color:var(--on-dark);padding:64px 0}.hb-page .hb-quote h2{color:#fff}.hb-page .hb-quote .hb-sub{color:var(--on-dark);max-width:none}.hb-page .hb-sendlist{margin-top:32px;display:grid;grid-template-columns:repeat(2,1fr);gap:2px 40px;list-style:none;padding:0;font-size:16px}.hb-page .hb-sendlist li{padding:10px 0;border-bottom:1px solid rgba(255,255,255,.12);color:var(--on-dark)}.hb-page .hb-sendlist li::before{content:\"\u2713\";color:var(--green);font-weight:700;margin-right:10px}@media(max-width:900px){.hb-page .hb-hero-grid,.hb-page .hb-two,.hb-page .hb-case,.hb-page .hb-reading{grid-template-columns:1fr}.hb-page .hb-hero{padding-top:32px}.hb-page .hb-sec{padding:40px 0}.hb-page .hb-kpis{grid-template-columns:repeat(2,1fr)}.hb-page .hb-cover>div,.hb-page .hb-fail>div{grid-template-columns:1fr;gap:8px}.hb-page .hb-tiers,.hb-page .hb-sendlist{grid-template-columns:1fr}.hb-page .hb-apps{grid-template-columns:repeat(2,1fr)}.hb-page .hb-case{padding:22px}}@media(max-width:600px){.hb-page h1{font-size:30px;max-width:none}.hb-page .hb-sec-h{font-size:26px}.hb-wrap{padding-left:20px;padding-right:20px}.hb-page .hb-lead{font-size:16px}.hb-page .hb-btn{padding:12px 18px;font-size:14px}.hb-page .hb-apps{grid-template-columns:1fr}.hb-page .hb-mosaic.four{grid-template-columns:repeat(2,1fr)}.hb-page table.hb-spec{min-width:600px}}@media(prefers-reduced-motion:reduce){.hb-page *{transition:none!important}}<\/style>\n<div class=\"hb-page\"><header class=\"hb-hero on-dark\"><div class=\"hb-wrap\"><div class=\"hb-hero-grid\"><div><h1>Custom Lithium Battery Packs for Medical Carts &amp; Portable Medical Devices<\/h1><p class=\"hb-lead\"><strong>Custom LiFePO4 and NMC packs<\/strong> built for hospital workstations on wheels (COWs), patient lifts, portable oxygen concentrators, and point-of-care in-vitro diagnostics. Supplied with UN 38.3 transport test summaries, IEC 62133-2 test reports per applicable model, dual-level hardware protection, and documentation to support OEM host evaluation under IEC 60601-1 and IEC 60601-1-2.<\/p><div class=\"hb-hero-cta\"><a class=\"hb-btn hb-btn-primary\" href=\"https:\/\/holobattery.com\/contact\/\">Send your medical device spec<\/a><a class=\"hb-btn hb-btn-ghost\" href=\"https:\/\/holobattery.com\/certifications-testing\/\">Certifications &amp; testing workflow<\/a><\/div><nav class=\"hb-toc\" aria-label=\"On this page\"><a href=\"#applications\">Target equipment<\/a><a href=\"#compliance\">Compliance scope<\/a><a href=\"#engineering\">Protection &amp; fuel gauge<\/a><a href=\"#builds\">Reference platforms<\/a><a href=\"#faq\">FAQ<\/a><\/nav><\/div><div class=\"hb-mosaic\"><a href=\"https:\/\/holobattery.com\/product\/custom-24v-30ah-lifepo4-drop-in-battery\/\"><img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/holobattery.com\/wp-content\/uploads\/2024\/10\/custom-24V-30Ah-lifepo4-drop-in-battery.png\" alt=\"24V 30Ah LiFePO4 battery pack for powered medical carts\" width=\"600\" height=\"600\" fetchpriority=\"high\"><span>24V 30Ah LiFePO4 (Carts)<\/span><\/a><a href=\"https:\/\/holobattery.com\/product\/custom-14-8v-10ah-ncm-pvc-wrap-battery\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/holobattery.com\/wp-content\/uploads\/2024\/10\/custom-14.8v-10ah-NCM-battery-pack.png\" alt=\"14.8V 10Ah NMC battery pack for portable medical devices\" width=\"600\" height=\"600\" loading=\"lazy\"><span>14.8V 10Ah NMC (Portable)<\/span><\/a><a href=\"https:\/\/holobattery.com\/product\/24v-60ah-lifepo4-battery\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/holobattery.com\/wp-content\/uploads\/2022\/08\/custom-24V-60Ah-lifepo4-drop-in-battery.png\" alt=\"24V 60Ah LiFePO4 battery pack for patient lifts and nursing workstations\" width=\"600\" height=\"600\" loading=\"lazy\"><span>24V 60Ah LiFePO4 (Workstations)<\/span><\/a><a href=\"https:\/\/holobattery.com\/product\/custom-25-2v-15ah-21700-battery-pack\/\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/holobattery.com\/wp-content\/uploads\/2025\/03\/custom-25.2V15Ah-ncm-battery.png\" alt=\"25.2V 15Ah 21700 battery pack for mobile diagnostics\" width=\"600\" height=\"600\" loading=\"lazy\"><span>25.2V 15Ah 21700 (Diagnostics)<\/span><\/a><\/div><\/div><\/div><\/header><nav class=\"hb-section-nav\" aria-label=\"Battery applications\"><div class=\"hb-wrap\"><a href=\"https:\/\/holobattery.com\/applications\/\">All applications<\/a><a href=\"https:\/\/holobattery.com\/applications\/medical-device-battery-packs\/\" aria-current=\"page\">Medical Devices<\/a><a href=\"https:\/\/holobattery.com\/applications\/sodium-ion-battery-packs\/\">Sodium-Ion<\/a><a href=\"https:\/\/holobattery.com\/applications\/agv-mobile-robot-batteries\/\">AGV &amp; Robots<\/a><a href=\"https:\/\/holobattery.com\/applications\/forklift-batteries\/\">Forklifts<\/a><a href=\"https:\/\/holobattery.com\/applications\/energy-storage-batteries\/\">Energy Storage<\/a><a href=\"https:\/\/holobattery.com\/applications\/cold-climate-commercial-vehicle-batteries\/\">Cold Climate &amp; Trucks<\/a><a href=\"https:\/\/holobattery.com\/applications\/marine-battery-packs\/\">Marine<\/a><\/div><\/nav><section class=\"hb-sec\"><div class=\"hb-wrap\"><div class=\"hb-kpis\"><div><b>IEC 62133-2<\/b><span>Test reports arranged per applicable model, plus UN 38.3 transport summaries<\/span><\/div><div><b>Dual-Stage<\/b><span>Primary BMS IC + independent secondary protector &amp; thermal fuse<\/span><\/div><div><b>\u00b11% SOC<\/b><span>TI \/ SMBus \/ I2C smart fuel gauging for accurate clinical runtime display<\/span><\/div><div><b>External Use<\/b><span>Carts, lifts, portable oxygen concentrators &amp; POC IVD (class confirmed by market)<\/span><\/div><\/div><\/div><\/section><section class=\"hb-sec tint\" id=\"applications\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">Medical equipment categories we build for<\/h2><div class=\"hb-tablewrap\" tabindex=\"0\" role=\"region\" aria-label=\"Medical battery pack categories and configurations\"><table class=\"hb-spec\"><thead><tr><th>Equipment Category<\/th><th>Typical Voltage &amp; Chemistry<\/th><th>Core Engineering Priorities<\/th><th>Reference Builds<\/th><\/tr><\/thead><tbody><tr><td><strong>Powered Medical Carts &amp; COWs<\/strong><br>(Workstations on wheels, medication carts)<\/td><td>12.8V \/ 25.6V LiFePO4 (20Ah\u2013100Ah)<\/td><td>3,000\u20135,000+ cycles for 24\/7 hospital shifts, hot-swap mechanical latching, fast charging between rounds, low heat dissipation.<\/td><td><a href=\"https:\/\/holobattery.com\/product\/custom-24v-30ah-lifepo4-drop-in-battery\/\">24V 30Ah LiFePO4<\/a> \u00b7 <a href=\"https:\/\/holobattery.com\/product\/24v-60ah-lifepo4-battery\/\">24V 60Ah LiFePO4<\/a><\/td><\/tr><tr><td><strong>Patient Lifts, Hospital Beds &amp; Rehab Mobility<\/strong><\/td><td>24V \/ 36V LiFePO4 or NMC (8Ah\u201330Ah)<\/td><td>High actuator lift current without voltage sag, sealed IP54\/IP65 wipe-down housings resistant to hospital disinfectants, low self-discharge.<\/td><td><a href=\"https:\/\/holobattery.com\/product\/custom-24v-8ah-18650-pvc-wrap-battery\/\">24V 8Ah 18650<\/a> \u00b7 <a href=\"https:\/\/holobattery.com\/product\/custom-25-2v-15ah-21700-battery-pack\/\">25.2V 15Ah 21700<\/a><\/td><\/tr><tr><td><strong>Portable Oxygen Concentrators, Handheld Ultrasound &amp; POC Diagnostics<\/strong><\/td><td>10.8V \/ 11.1V \/ 14.4V \/ 14.8V NMC (18650 \/ 21700)<\/td><td>High Wh\/kg for patient carry weight, FAA-friendly &lt;100 Wh or &lt;160 Wh sizing, SMBus\/I2C impedance-tracking fuel gauge, custom plastic ABS\/PC enclosures.<\/td><td><a href=\"https:\/\/holobattery.com\/product\/custom-14-8v-10ah-ncm-pvc-wrap-battery\/\">14.8V 10Ah NMC<\/a> \u00b7 <a href=\"https:\/\/holobattery.com\/product\/custom-11-1v-9ah-18650-pvc-wrap-battery-pack\/\">11.1V 9Ah 18650<\/a><\/td><\/tr><\/tbody><\/table><\/div><\/div><\/section><section class=\"hb-sec\" id=\"compliance\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">What we certify vs. what stays at the host device<\/h2><div class=\"hb-prose\"><p>Battery pack certifications and host medical device approvals are separate test scopes. Here is how responsibility splits on every program.<\/p><\/div><div class=\"hb-tablewrap\" tabindex=\"0\" role=\"region\" aria-label=\"Medical battery compliance scope\"><table class=\"hb-spec\"><thead><tr><th>Standard<\/th><th>Responsibility &amp; Deliverable<\/th><\/tr><\/thead><tbody><tr><td><strong>UN 38.3<\/strong><\/td><td>Transport testing and test summaries provided per shipped pack configuration, alongside MSDS and air\/sea shipping documentation.<\/td><\/tr><tr><td><strong>IEC 62133-2<\/strong><\/td><td>Pack-level safety test reports arranged through accredited laboratories per applicable model and configuration.<\/td><\/tr><tr><td><strong>UL 1642 \/ UL 2054<\/strong><\/td><td>Built with UL 1642 recognized Grade A cells; pack-level UL 2054 testing arranged per North American project scope.<\/td><\/tr><tr><td><strong>IEC 60601-1 &amp; IEC 60601-1-2 (EMC)<\/strong><\/td><td>Evaluated at the complete host medical device level by the OEM. We support OEM basic safety, essential performance, and EMC evaluation with redundant protection schematics, isolated communication interfaces, low-EMI BMS PCB layouts, UL94 V-0 housing materials, and BOM traceability files.<\/td><\/tr><tr><td><strong>Intended Use &amp; Regulatory Scope<\/strong><\/td><td>We build packs for external and portable medical equipment: powered medical carts (COWs), patient lifts, hospital beds, portable oxygen concentrators, handheld ultrasound, and point-of-care in-vitro diagnostic analyzers. We do not build implantable or life-support batteries. Final device classification (such as US FDA Class I\/II, EU MDR Class I\/IIa\/IIb, or EU IVDR) is confirmed by the medical OEM based on target market and intended use.<\/td><\/tr><\/tbody><\/table><\/div><p class=\"hb-note\">For full details on our per-pack EOL inspection, batch cycle testing, and certification test workflow, see our <a href=\"https:\/\/holobattery.com\/certifications-testing\/\">Certifications &amp; Testing<\/a> page.<\/p><\/div><\/section><section class=\"hb-sec tint\" id=\"engineering\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">Protection redundancy, fuel gauging, and wipe-down housings<\/h2><div class=\"hb-prose\"><p>Hospital batteries stay on docking chargers for long stretches, get wiped down daily with isopropyl alcohol or quaternary ammonium disinfectants, and need accurate remaining-runtime readings.<\/p><p>For single-fault safety, we pair the primary BMS IC with an independent secondary over-voltage\/over-current protector and a physical thermal or chemical fuse. Impedance-tracking SMBus or I2C fuel gauges report remaining minutes, state of health (SOH), cycle count, and fault flags directly to your cart or handheld display.<\/p><p>Hot-swap packs use blind-mate power and signal connectors rated for thousands of insertions, inside UL94 V-0 ABS\/PC or powder-coated enclosures sealed against wipe-down moisture. Every shipped pack carries a serial number linked to its cell lot, BMS firmware version, and per-pack EOL electrical test log.<\/p><\/div><\/div><\/section><section class=\"hb-sec\" id=\"builds\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">Typical development schedule for medical OEMs<\/h2><div class=\"hb-prose\"><p>Most medical programs follow four steps: electrical and mechanical DFM review (1 to 3 business days), functional prototypes with calibrated SMBus\/I2C firmware (2 to 3 weeks), formal UN38.3 and IEC 62133-2 lab testing (4 to 6 weeks), and locked-BOM pilot or volume runs with lot traceability. MOQ starts at 100 packs for standard enclosures and 300+ packs for custom injection-molded housings.<\/p><\/div><\/div><\/section><section class=\"hb-sec tint\" id=\"faq\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">Frequently asked questions<\/h2><div class=\"hb-faq\"><details><summary>Do your medical battery packs come with IEC 60601-1 certification?<\/summary><div class=\"a\">No. IEC 60601-1 and IEC 60601-1-2 are evaluated on the complete medical electrical system, not on a standalone battery pack. We arrange UN 38.3 transport test summaries and IEC 62133-2 test reports per applicable model (and UL 2054 where required), and supply dual-protection schematics, UL94 V-0 housing materials, low-EMI BMS layouts, and BOM documentation to support the OEM during host basic safety, essential performance, and EMC testing.<\/div><\/details><details><summary>Which medical applications do you support, and how is device class determined?<\/summary><div class=\"a\">We build packs for external and portable equipment: powered medical carts (COWs), patient lifts, hospital beds, portable oxygen concentrators, handheld ultrasound, and point-of-care in-vitro diagnostic analyzers. We do not build implantable or life-support batteries. Because regulatory frameworks differ by market (US FDA Class I\/II, EU MDR Class I\/IIa\/IIb, and EU IVDR for in-vitro diagnostics), final device classification is confirmed by the medical OEM for its target market and intended use.<\/div><\/details><details><summary>Can you build FAA-compliant packs under 100 Wh or 160 Wh for portable patient devices?<\/summary><div class=\"a\">Yes. For portable oxygen concentrators and home-care monitors that travel on commercial flights, we size 3S or 4S 18650\/21700 packs strictly under 100 Wh (or 100\u2013160 Wh with airline approval) and provide full UN38.3 test summaries.<\/div><\/details><details><summary>How do you ensure BOM stability for multi-year medical product lifecycles?<\/summary><div class=\"a\">Once your design passes qualification, we lock the approved cell model, BMS IC, connector, and enclosure resin under a controlled BOM. Any proposed component change requires written OEM notification and re-validation before production.<\/div><\/details><\/div><\/div><\/section><section class=\"hb-sec\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">Further reading<\/h2><div class=\"hb-reading\"><a href=\"https:\/\/holobattery.com\/custom-lithium-battery-solutions-for-portable-oxygen-concentrators-balancing-weight-and-runtime\/\"><b>Portable Oxygen Concentrator Batteries<\/b><span>Balancing carry weight, runtime, and FAA Wh limits.<\/span><\/a><a href=\"https:\/\/holobattery.com\/certifications-testing\/\"><b>Certifications &amp; Testing<\/b><span>UN38.3, IEC 62133-2, UL 2054, and EOL QC workflow.<\/span><\/a><a href=\"https:\/\/holobattery.com\/custom-batteries\/\"><b>Custom Battery Design Guide<\/b><span>Seven engineering stages from spec to mass production.<\/span><\/a><a href=\"https:\/\/holobattery.com\/oem-private-label-battery-packs\/\"><b>OEM &amp; Private-Label Packs<\/b><span>Tooling ownership, NDA terms, and contract deliverables.<\/span><\/a><\/div><\/div><\/section><section class=\"hb-quote\"><div class=\"hb-wrap\"><h2 class=\"hb-sec-h\">Send your medical device battery specification<\/h2><p class=\"hb-sub\">Share your device class, target runtime, and certification markets so our engineers can prepare a preliminary pack architecture and compliance checklist:<\/p><ul class=\"hb-sendlist\"><li>Device type (medical cart, patient lift, POC diagnostics, or portable therapy)<\/li><li>Nominal voltage, target Wh\/Ah, and peak current<\/li><li>Physical envelope, weight limit, and hot-swap connector needs<\/li><li>Communication protocol (SMBus, I2C, CAN, or analog fuel gauge)<\/li><li>Target markets and required pack certifications (UN38.3, IEC 62133-2, UL 2054)<\/li><li>Expected prototype schedule and annual volume<\/li><\/ul><a class=\"hb-btn hb-btn-primary\" style=\"margin-top:32px\" href=\"https:\/\/holobattery.com\/contact\/\">Request a medical battery spec review<\/a><\/div><\/section><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Service\",\"name\":\"Custom Medical Cart & Portable Medical Device Battery Pack Manufacturing\",\"provider\":{\"@type\":\"Organization\",\"name\":\"Holo Battery\",\"url\":\"https:\/\/holobattery.com\/\"},\"serviceType\":\"OEM Medical Battery Pack Design & Assembly\",\"areaServed\":\"Worldwide\",\"description\":\"Custom LiFePO4 and NMC battery packs for powered medical carts, patient lifts, portable oxygen concentrators, and point-of-care in-vitro diagnostics, with UN 38.3 transport summaries, IEC 62133-2 test reports per applicable model, and IEC 60601-1 OEM evaluation documentation.\"},{\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Do your medical battery packs come with IEC 60601-1 certification?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. IEC 60601-1 and IEC 60601-1-2 are evaluated on the complete host medical device. We arrange UN 38.3 transport test summaries and IEC 62133-2 test reports per applicable model and provide dual-protection schematics, UL94 V-0 housing data, and low-EMI BMS documentation to support OEM basic safety, essential performance, and EMC evaluation.\"}},{\"@type\":\"Question\",\"name\":\"Which medical applications do you support, and how is device class determined?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"We build packs for external and portable equipment including powered medical carts, patient lifts, hospital beds, portable oxygen concentrators, handheld ultrasound, and point-of-care IVD analyzers, excluding implantable and life-support devices. Final device class under US FDA, EU MDR (Class I\/IIa\/IIb), or EU IVDR is confirmed by the OEM per target market.\"}},{\"@type\":\"Question\",\"name\":\"Can you build FAA-compliant packs under 100 Wh or 160 Wh for portable patient devices?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. We size 3S or 4S 18650\/21700 packs under 100 Wh or 160 Wh with UN38.3 documentation for travel-ready portable medical equipment.\"}},{\"@type\":\"Question\",\"name\":\"How do you ensure BOM stability for multi-year medical product lifecycles?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"After qualification, we lock the approved cell, BMS IC, connector, and housing material under a controlled BOM with written change control.\"}}]}]}<\/script><\/div>","protected":false},"excerpt":{"rendered":"<p>Custom Lithium Battery Packs for Medical Carts &amp; Portable Medical Devices Custom LiFePO4 and NMC packs built for hospital workstations on wheels (COWs), patient lifts, portable oxygen concentrators, and point-of-care in-vitro diagnostics. Supplied with UN 38.3 transport test summaries, IEC 62133-2 test reports per applicable model, dual-level hardware protection, and documentation to support OEM host [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":9002,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-9636","page","type-page","status-publish"],"_links":{"self":[{"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/pages\/9636","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/comments?post=9636"}],"version-history":[{"count":0,"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/pages\/9636\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/pages\/9002"}],"wp:attachment":[{"href":"https:\/\/holobattery.com\/wp-json\/wp\/v2\/media?parent=9636"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}