Compliance, Quality & Lab Verification

Battery Testing & Compliance Support

See what we test in-house, which reports are available for your battery design, and how we support third-party testing and shipping documentation for U.S. and European projects.

Automated EOL Test Bench Per-Unit Logging
Automated battery pack end-of-line comprehensive testing bench with live pass-fail diagnostics
100% EOL
Per-unit OCV, IR, BMS cutoff, and comms logged before dispatch
ΔEN < 3 mΩ
Automated incoming cell sorting for voltage and impedance balance
UN 38.3 + SDS
Model-specific shipping summaries and Class 9 DG packaging
UL & IEC
Verified cell files plus project-coordinated pack lab testing
Global Market Compliance

Standards, Documents & Certification Scope

We separate cell-level certificates, model-specific pack reports, factory test records, and third-party certification support so your compliance team knows exactly what is ready on day one and what requires project lab testing.

Standard / DocumentTarget MarketDomeinWhat Holo Provides
UN 38.3 Test SummaryGlobal Air & Sea FreightMandatory lithium transport tests (altitude, thermal, vibration, shock, short-circuit) per pack designModel-Specific Test Summary Cell UN 38.3 files supplied immediately; pack-level UN 38.3 testing and Test Summaries are coordinated for each new custom SKU (full third-party lab reports available under project NDA).
SDS (Safety Data Sheet)Global Customs & Carriers16-section chemical and hazard transport declaration matching the shipped packShipment Document Issued per model and updated for current IATA air and IMDG ocean freight rules.
UL 1642United States & CanadaSafety standard for individual lithium cellsCell File Grade A Tier-1 cells supplied with active UL 1642 recognition files verifiable before sample build.
UL 1973North AmericaStationary energy storage, vehicle auxiliary power, and light electric rail applicationsProject-Coordinated 3rd-Party Enclosure, thermal barrier, and BMS architecture designed to UL 1973 criteria with accredited lab sample support.
UL 2054 / UL 2271 / UL 2580North AmericaPortable commercial packs (2054), light electric vehicles (2271), and motive fleet packs (2580)Project-Coordinated 3rd-Party Pre-compliance thermal, isolation, and fault-injection engineering plus dedicated lab test samples.
IEC 62133-2 / IEC 62619European Union, UK & CBPortable sealed packs (62133-2) and industrial stationary or motive packs (62619)Project-Coordinated 3rd-Party Creepage/clearance layout, redundant BMS cutoffs, and CB Scheme test coordination through accredited labs.
EU Battery Regulation (2023/1542)European UnionCE conformity, restricted substances, labeling, and lot traceability for EU importersEU Technical File Support BOM substance declarations, RoHS/CE support documents, and serialized QR lot traceability aligned with your EU importer responsibilities.

Why We Separate Cell Certification From Pack Certification

A cell certificate (such as UL 1642) does not certify a newly designed battery pack. Final pack certification depends on your mechanical enclosure, BMS protection logic, and thermal layout. We provide verified cell files up front, engineer the assembly toward your target standard, run in-house pre-checks, and build test units for accredited third-party certification labs.

Manufacturing Quality Control

Five Quality Gates From Incoming Cells to Dispatch

Prototype packs that work on an engineering bench still fail in the field if batch consistency slips during production. Production lots move through five logged inspection gates.

GATE 01

Incoming Cell Grading (IQC)

Verify factory QR codes, spot-check capacity, and sort every lot by OCV (ΔV < 5 mV) and internal resistance (ΔEN < 3 mΩ).

GATE 02

Weld & Torque Control

Calibrated laser busbar welding, pull-force sampling, and logged torque values on bolted high-current terminals.

GATE 03

BMS & Protocol Calibration

Verify OVP, UVP, OCP, and NTC thermal cutoffs alongside CANbus, RS485, or SMBus handshake frames.

GATE 04

EOL & Lot Verification

Per-unit EOL electrical checks on every pack, paired with batch cycling and model-specific environmental tests.

GATE 05

Serialized Traceability & RMA

Each pack serial number ties back to its cell lot, BMS batch, and factory test record for rapid root-cause tracing.

Clear Scope of Factory Testing: Every single finished pack receives mandatory 100% EOL checks (open-circuit voltage, internal resistance, charge/discharge function, BMS protection cutoffs, and communication handshake). Lot-based or model-specific tests (multi-cycle capacity aging, whole-pack IP67/IP68 airtightness pressure decay, tri-axial vibration, and high-voltage dielectric withstand) are executed according to the project specification and sample plan.
In-House Equipment

Inside Our Verification & Inspection Benches

Running electrical, mechanical, and sealing checks on our own benches catches design issues before third-party certification testing begins.

Automated cell internal resistance and open-circuit voltage sorting equipment

Cell IR & OCV Matching System

Sorts incoming cylindrical and prismatic cells before welding so series and parallel groups age evenly.

Tests & Logs: AC/DC internal resistance (ΔIR), open-circuit voltage (ΔV), and lot bin assignment.
Tri-axial transit and motive vibration testing platform

Tri-Axial Vibration Testing

Validates cell brackets, busbar welds, and wire harness strain relief for AGVs, forklifts, marine hulls, and vehicles.

Tests & Logs: Sweep frequency/duration profile, post-test voltage stability, and mechanical inspection sign-off.
Multi-channel battery pack aging and charge-discharge cycling racks

Multi-Channel Aging & Cyclusrekken

Runs controlled charge-discharge cycles on sample and production lots under monitored thermal conditions.

Tests & Logs: Deliverable Ah/Wh capacity, cell-group balance drift, and charge/discharge curve logs.
Whole-pack airtightness pressure decay test log for IP67 and IP68 waterproof enclosures

Whole-Pack Airtightness (IP67 / IP68)

Verifies gasket compression, connector glands, and enclosure welds on sealed marine and outdoor packs.

Tests & Logs: Applied pressure setpoint, hold time, pressure-decay delta (Pa), and pass/fail serial log.
Dielectric withstand and high-voltage insulation resistance tester

Diëlektrisch & Insulation Withstand

Checks electrical isolation between live busbars and metallic housings on 48V to 96V+ industrial platforms.

Tests & Logs: Insulation resistance (MΩ), hi-pot withstand voltage, and leakage current threshold.
Inline battery pack assembly and station quality verification line at Holo Battery

Inline Assembly & Station Inspection

In-process checks across cell grouping, BMS wiring, and enclosure closure prior to final EOL testing.

Tests & Logs: Station checklist sign-off, fastener torque check, polarity verification, and barcode pairing.
Exporteren & Handover

Documentatie & Dangerous-Goods Freight Package

Lithium batteries are regulated Class 9 dangerous goods. We prepare UN-certified packaging and structured technical handover files for U.S., EU, and UK customs clearance.

Engineering & Production Handover Files

Available with prototype sign-off and serial OEM production batches:

  • 3D CAD (.STEP) models and 2D dimensional drawings
  • Electrical schematic, connector pinouts, and wire harness spec
  • BMS protection matrix and CANbus / RS485 protocol table
  • Cell-level UL / IEC / UN 38.3 files and Grade A incoming records
  • Serialized end-of-line (EOL) factory test ledger per unit

U.S. & European Dangerous-Goods Export Support

Prepared for air express prototypes and sea-freight commercial lots:

  • Model-specific UN 38.3 Test Summary and 16-section SDS
  • UN-certified dangerous-goods cartons and Class 9 hazard labeling
  • Air freight (DHL / FedEx DG) and sea freight (DDP / CIF / FOB)
  • RoHS material declarations and CE technical file support for EU importers
  • Mutual NDA signed within 2 hours prior to sharing drawings

Planning a Certified Pack for the U.S. or European Market?

Share your target certification standard, operating temperature, and annual volume. Our engineering team will review cell files, pre-compliance design needs, and realistic lab timelines within 8 business hours.

Fast-Track Your Compliance Assessment

  • Target regions (United States, EU, UK, Canada, ANZ)
  • Required standards (UN 38.3, UL 1973/2054/2271, IEC 62133/62619)
  • Nominal voltage, capacity, and peak discharge current
  • Enclosure material and IP65 / IP67 / IP68 target
  • Estimated annual volume and sample launch date

Gratis Offerte Aanvragen

Stuur de applicatiegegevens en wij bevestigen of deze configuratie past bij uw spannings-, stroom-, behuizings- en communicatievereisten. Wij reageren binnen 8 kantooruren; let op een e-mail van “@holobattery.com”.